Polycom ViewStation EX Microscope & Magnifier User Manual


 
ViewStation EX, ViewStation FX, and VS4000 API Guide
156 www.polycom.com
textinput <"text to input">
Description
This command inserts text into a user interface edit box that you
have already selected using the remote control.
text to input Alphanumeric string to be inserted into the
selected edit box.
Note Use quotation marks around a compound name or strings
containing spaces (Ex: “united states” or “111 222 333”).
Example
textinput "My Test VS4000"
This command would insert the text "My Test VS4000" into a
selected user interface edit box (for example, the System Name edit
box in the General Setup screen of the user interface).
timediffgmt <{-12:00..+00:00..+12:00}|get>
Description
This command sets the time difference from where the system is
installed and Greenwich Mean Time (GMT). This allows the GMS
(Global Management System) to view the local time of the managed
system.
-12:00..+00:00..+12:00
Range of time differences. +00:00 is GMT time.
get Displays the current setting.
Example
timediffgmt -6:00
textinput