Mitsubishi Electronics MR-MC240 Sleep Apnea Machine User Manual


 
11 - 33
11. PARAMETERS
Parameter
No.
Symbol Name
Initial
Value
Units
Setting
range
Function
When tandem
drive is being
used
026C TZOFL Tandem
drive home
position
signal offset
(lower)
0000h
Command
Units
0000h
to FFFFh
Set the amount of offset for the home position signal
position while in tandem drive axes mode.
(Used when performing home position return using
the scale home position signal detection method.)
Master
026D TZOFH Tandem
drive home
position
signal offset
(upper)
0000h 0000h
to FFFFh
026E *TOFS Tandem drive
deviation
compensation
units
multiplication
0
0 to
32767
Set the multiplication for valid width of tandem drive
deviation compensation.
(Note) When the setting value is 0, the multiplication
is 1 times.
Master
026F
For
manufacturer
setting
0
0270 0
0271 0
0272 0
0273 0
0274 0
0275 0
0276 0
0277 0
0278 0
0279 0
027A 0
027B 0
027C 0
027D 0
027E 0
027F 0
0280 0
0281 *IOP Interference
check
Options
0000h
0000h to
1FF1h
Interference check
Set validity/invalidity of
interference check.
0: Invalid
1: Valid
Interference check axis
Set the opposing axis for
performing interference check.
00h to 1Fh: Interference check
axis 1
Example: 0: axis number 1
Interference check coordinate
direction
Set the direction of the
coordinate system for the axis
from the perspective of the
standard coordinate system.
0: Same direction
1: Opposite direction
Master