Mitsubishi Electronics MR-MC240 Sleep Apnea Machine User Manual


 
10 - 9
10. TABLE MAP
(3) Command bit
For each bit, 0 stands for invalid and 1 stands for valid.
Address Bit Symbol Signal name Address Bit Symbol Signal name
03E0
0 ITE Interrupt processing complete
03E1
0 SMPS Sampling start
1 ITS Interrupt output valid 1
Reserved
2
Reserved
2
3 3
4 HMA During user program memory access 4
5
Reserved
5
6 6
7 7
Address Bit Symbol Signal name Address Bit Symbol Signal name
03E2
0 SEMI Software forced stop (Note)
03E3
0
Reserved
1
Reserved
1
2 2
3 3
4 4
5 5
6 6
7 7
Address Bit Symbol Signal name Address Bit Symbol Signal name
03E4
0 ITFE
Interrupt processing high speed
complete
03E5
0
Reserved
1
Reserved
1
2 2
3 3
4 4
5 5
6 6
7 7
Address Bit Symbol Signal name Address Bit Symbol Signal name
03E6
0 ASYN1
Non-synchronous command
(group 1)
03E7
0
1 ASYN2
Non-synchronous command
(group 2)
1
2 ASYN3
Non-synchronous command
(group 3)
2
3 ASYN4
Non-synchronous command
(group 4)
3
Reserved
4 ASYN5
Non-synchronous command
(group 5)
4
5 ASYN6
Non-synchronous command
(group 6)
5
6 ASYN7
Non-synchronous command
(group 7)
6
7 ASYN8
Non-synchronous command
(group 8)
7
Note. Software forced stop is a normally-open contact (an external forced stop is a normally-closed contact). When the signal is
turned on, the status becomes forced stop status. This is different than an external forced stop, in that it is performed through
software processing.