Mitsubishi Electronics MR-MC240 Sleep Apnea Machine User Manual


 
7 - 63
7. AUXILIARY FUNCTION
7.12.9 Sampling data read
Sampled data of 8192 points is stored in the sampling data buffer area of the position board internal memory.
Sampled data is transferred to the sampling data read area divided in units of a page (32 points/page). For the
sampling data read during the sampling, refer to the Section 7.12.10.
(1) Sampling data read area
Transferred on
a per page basis
Sampling data buffer area
Page
number Page details
n: page number
BE00h 1
st
point + (n - 1) 32
BE84h 2
nd
point + (n - 1) 32
BF08h 3
rd
point + (n - 1) 32
:
CD78h 31
st
point + (n - 1) 32
CDFCh 32
nd
point + (n - 1) 32
Sampling data
read area
1
st
point
+0000h
Sampling data 1
1
to
+0004h
Sampling data 2
32
nd
point
+0008h
Sampling data 3
33
rd
point
+000Ch
Sampling data 4
2
to
+0010H
Sampling data 5
64
th
point
+0014h
Sampling data 6
:
+0018h
Sampling data 7
+001Ch
Sampling data 8
+0020h
Sampling data 9
8161
st
point
+0024h
Sampling data 10
256
to
+0028h
Sampling data 11
8192
nd
point
+002Ch
Sampling data 12
+0030h
Sampling data 13
+0034h
Sampling data 14
+0038h
Sampling data 15
+003Ch
Sampling data 16
+0040h Sampling data 17
+0044h
Sampling data 18
+0048h Sampling data 19
+004Ch
Sampling data 20
+0050H
Sampling data 21
+0054h
Sampling data 22
+0058h
Sampling data 23
+005Ch Sampling data 24
+0060h Sampling data 25
+0064h
Sampling data 26
+0068h
Sampling data 27
+006Ch
Sampling data 28
+0070h
Sampling data 29
+0074h
Sampling data 30
+0078h
Sampling data 31
+007Ch
Sampling data 32
+0080h
Sampling bit information 1 to 16
+0082h
Reserved (2 bytes)