Upgrading CMS to the High Availability Option
CentreVu
CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Setting Up the NTS 3-62
10. Enter the appropriate Subnet mask, or press Enter to accept the
default. The program responds:
11. Enter the IP address of the CMS computer. The program responds:
12. Press Enter to accept the default broadcast message address. The
program responds:
13. Enter the IP address of the CMS computer. The program responds:
14. Press Enter to accept the default IP packet encapsulation. The
program returns to the monitor:: prompt if you have a 64-port
NTS. Continue with Step 16
.
The program responds with the following question if you have an 8-
or 16-port NTS:
15. Enter N. The program returns to the monitor:: prompt.
Subnet mask:
xxx.xxx.xxx.xxx
Enter preferred load host Internet address [<any host>]::
Preferred load host address
xxx.xxx.xxx.xxx
Enter Broadcast address [0.0.0.0]::
Enter Preferred dump address [0.0.0.0]::)
Preferred dump address:
xxx.xxx.xxx.xxx
Select type of IP packet encapsulation (ieee802/ethernet)
[<ethernet>] ::
Type of IP packet encapsulation: <ethernet>
Load Broadcast Y/N [Y]::