Lucent Technologies Release 3 Version 8 Medical Alarms User Manual


 
Administering the Switch for CMS High Availability Systems
CentreVu
CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Administering the Definity Switch 4-9
Field Definition
Packet Intf2 Enter y to add a second packet interface.
Bus Bridge Enter the equipment location of the CLAN
circuit pack that does the bus bridge
functionality when the packet bus is
activated. This must be administered for the
CLAN to work.
Inter-Board Link Timeslots — The total number of timeslots allocated
cannot be greater than 11.
Inter-Board Link
Timeslot Pt0
Enter the number of timeslots (1-9) used by
this port. Port 0 carries the bulk of messaging
traffic between the switch and the CMS. The
default of 6 should be adequate, but can be
increased (if needed) to improve traffic flow.
Inter-Board Link
Timeslot Pt1
Enter the number of timeslots (1-3) used by
this port. Port 1 is a low traffic port and
should always be set to 1.
Inter-Board Link
Timeslot Pt2
Enter the number of timeslots (1-3) used by
this port. Port 2 is a low traffic port and
should always be set to 1.