Furuno BR-1000 Medical Alarms User Manual


 
FURUNO
BR-1000
SPECIFICATIONS OF BRIDGE ALARM SYSTEM
BR-1000
1 BRIDGE PANEL
1.1 Indication system 7-inch color LCD, 480 x 234 dots
1.2 Brilliance 0.4 to 700 cd
1.3 Status indication Alarm and status
1.4 Alarm control Alarm acknowledge, watch safety alarm and reset control
1.5 Alarm information output 1 ch (for VDR)
1.6 LAN 1 ch (for processor unit)
1.7 Clock input 1 ch (for GPS)
2 PROCESSOR UNIT
2.1 LAN Ethernet: 100base-TX
2.2 Input port
Alarm 48 ch
Local ACK 12 ch
Operator’s fitness 7 ch
Cabin panel test 5 ch
Autopilot mode HCS mode: 1ch, TCS mode: 1 ch
Power fail 1 ch
2.3 Output port
Remote ACK 12 ch
System failure 2 ch
External siren 1 ch
2.4 MODBUS 2 ch (for IAS)
2.5 Cabin panel control 14 sets max. (4 sets: parallel connection)
2.6 Timer reset panel control 4 sets max.
3 CABIN PANEL
3.1 Input voltage 12VDC: 3.5 mA or less (supplied from processor unit)
3.2 Visible alarm Alarm lamp, Duty lamp
3.3 Audible alarm Buzzer
4 TIMER RESET PANEL/ WATERTIGHT TIMER RESET PANEL
4.1 Input voltage 12VDC: 3.5 mA or less (supplied from processor unit)
4.2 Visible alarm Watch alarm lamp, Bridge alarm lamp
4.3 Audible alarm Buzzer
4.4 Signal output Timer reset
SP - 1 E4450S01B
090324