Furuno BR-1000 Medical Alarms User Manual


 
2. BRIDGE PANEL
2-6
2.5 Alarm Sequence
2.5.1 Bridge alarm
1. When a device connected to the system gives an alarm, the Bridge Panel gives
the audible alarm and flashes the BRIDGE ALARM box in red. The information
area shows the name of the alarm.
Bridge alarms given
2. Press the BUZ STOP key on the Bridge Panel to stop the buzzer and the ACK
key to acknowledge the alarm. Confirm the alarm also at the device that gave the
alarm. The Bridge Panel shows the Alarm List, an example of which is shown be-
low.
The buzzer stops only at the equipment which has the Remote ACK Out signal
connected to this equipment.
The Alarm List shows in yellow the alarms for which their cause have not yet been
removed.
Note: In the one-man mode, if the BUZ STOP and ACK keys are not operated
within 30 seconds after an alarm is given, the alarm is sent to the quarters of the
back-up officer and all public areas. If the alarm is still not acknowledged within
the selected time interval, the alarm is sent to the quarters of all the navigation of-
ficers.
WATCH
ALARM
MODE
ONEMAN
BACK-UP
C/OFFICER
TIME INTERVAL
3 MIN
BRIDGE
ALARM
Description
Priority
Tag
Auto Alarm Pop-up Display
004
028
No.1 Radar CPA/TCPA/GZ
Urgency
No.1 GPS Off-Track
Primary
BRIDGE
ALARM
Flashing in
red
Alarm name
WATCH
ALARM
MODE
ONEMAN
BACK-UP
C/OFFICER
TIME INTERVAL
3 MIN
BRIDGE
ALARM
No.1 Radar Sys Fail
No.2 Radar Sys Fail
No.3 Radar Sys Fail
No.1 Radar CPA/TCPA/GZ
No.2 Radar CPA/TCPA/GZ
No.3 Radar CPA/TCPA/GZ
No.1 RADAR System Error
No.2 RADAR System Error
Description
Secondary
Priority
001
002
003
004
005
006
007
008
Tag
Secondary
Secondary
Urgency
Urgency
Urgency
Secondary
Secondary
1 2 3 4 5 6 7 8 9
10 11 12