Furuno BR-1000 Medical Alarms User Manual


 
3. TIMER RESET PANEL, CABIN PANEL
3-2
• DNV mode
1) The WATCH/RESET button flashes (in yellow) every second from 30 seconds
before the selected time interval ends and continues until 15 seconds before the
interval ends.
2) The WATCH/RESET button flashes (in yellow) every second for an additional
15 seconds before the selected time interval ends, accompanied by a 15-sec-
ond audible alarm.
You can reset the watch alarm at the 1st stage (before the alarm is sent to the next
stage) with the WATCH/RESET button (yellow) on the Timer Reset Panel. If the alarm
is sent to the 2nd or 3rd stage, the alarm cannot be stopped from the Timer Reset Pan-
el. To acknowledge the alarm from the 2nd or 3rd stage, use the BUZ STOP and ACK
keys on the Bridge Panel.
Note 1: Press the WATCH/RESET button with a touch-and-release action to reset the
watch timer. The watch timer is not reset if the button is pressed and held.
Note 2: You can test the lamps in the buttons and the buzzer individually if you press
the WATCH/RESET and BRIDGE ALARM buttons together.