Furuno BR-1000 Medical Alarms User Manual


 
4. ADMINISTRATOR MENU (Initial Settings)
4-3
7. Press the ESC key to quit. You are asked “Do you want to save?”.
8. Use the arrow pads to select Yes then press the ENTER key.
Your settings are saved then the standby display appears. If you select No, the set-
tings are not saved and the Alarm List appears. Use Cancel to return to the Adminis-
trator menu.
Note: After the menu is closed, the bridge alarm and watch safety alarm are reset. In
the “Pending” condition the menu is open then closed and the bridge alarm starts from
the 1st stage. (This also occurs if there is no key operation at the password entry
screen for one minute.) if this occurs, use the BUZ STOP and ACK keys to stop the
alarm. If those keys are not operated, the alarm is forwarded to the Cabin Panel.
The next several sections describe the contents of the Administrator menu.
4.2 Mode Select (Operation Mode)
There are three operation modes. The operation of the bridge alarm and watch safety
alarm changes with the operating mode.
*
1
HCS=Heading Control System
*
2
TCS=Track Control System
*
3
SYS FUNC=System Function
*
4
ALM FWD=Alarm forward
Operation
mode
Bridge alarm Watch safety alarm
HCS*
1
or TCS*
2
:
OFF
HCS or TCS: ON HCS or TCS: OFF HCS or TCS: ON
SYS
FUNC*
3
ALM
FWD*
4
SYS
FUNC
ALM
FWD
SYS
FUNC
ALM
FWD
SYS
FUNC
ALM
FWD
Harbour OFF None OFF None OFF None OFF None
Bridge
Attended
OFF None ON Yes ON None ON None
One-Man ON Yes ON Yes ON Yes ON Yes
WATCH
ALARM
MODE
ONEMAN
BACK-UP
C/OFFICER
TIME INTERVAL
3 MIN
BRIDGE
ALARM
Back-up Officer Select
Captain Back-up
Watch Time Interval Select
All Back-up Officer Call Interval
Mode Select
3 min
OneMan
C/Officer
Description
Set
120 sec
Enable
Administrator Menu
Do you want to save ?
Yes
No Cancel