2. BRIDGE PANEL
2-8
3) If the RESET/WATCH key on the Timer Reset Panel is not operated.
Note: The watch alarm timer continues to operate during an active bridge alarm.
The sequence of the watch safety alarm is as follows:
1. After turning on the Bridge Panel and the standby display appears, the timer for
the watch safety alarm starts.
The yellow bar in the setting indication in the TIME INTERVAL box (lower left cor-
ner) moves right as the end of the selected time interval nears.
The time interval is set on the Administrator Menu. See Chapter 4.
When the end of the time interval has come, the yellow bar completely fills the bot-
tom half of the TIME INTERVAL box. The timing for the beginning of the alarm is
different between the IMO and DNV modes. The time interval indication is filled as
follows:
• DNV mode: The progress bar fills the time interval indication area 30 seconds
BEFORE
the time interval has come.
• IMO mode: The progress bar fills the time interval indication area AFTER
the
time interval has come.
2. When the operator fitness signal is input before the progress bar completely fills,
the timer is reset and the bar is erased.
3. The progress bar fills the interval indication and the Bridge Panel releases a 15-
second visual alarm. The WATCH ALARM box flashes in red and the message
PREWARNING WATCH ALARM appears in the information area.
WATCH
ALARM
MODE
ONEMAN
BACK-UP
C/OFFICER
BRIDGE
ALARM
BRIDGE ALARM SYSTEM BR-1000
NO ALARM
TIME INTERVAL
3 MIN
WATCH
ALARM
MODE
ONEMAN
BACK-UP
C-OFFICER
BRIDGE
ALARM
BRIDGE ALARM SYSTEM BR-1000
PREWARNING
WATCH ALARM
TIME INT
3 MIN
WATCH
ALARM
MODE
ONEMAN
BACK-UP
C/OFFICER
BRIDGE
ALARM
BRIDGE ALARM SYSTEM BR-1000
PREWARNING
WATCH ALARM
TIME INTERVAL
3 MIN