Furuno BR-1000 Medical Alarms User Manual


 
2. BRIDGE PANEL
2-9
4. If there is no operator fitness signal input within the 15-second visual alarm, the
Bridge Panel releases a 15-second audible alarm (buzzer). The WATCH ALARM
box continues to flash in red and the message WARNING! WATCH ALARM ap-
pears in the information area.
5. If there is no operator fitness signal input within 15 seconds, the Cabin Panel in
the quarters of the back-up officer and all the Cabin Panels in public areas give
audible and visual alarms.
Note: The alarm cannot be stopped from a Cabin Panel.
6. At the Bridge Panel, stop the buzzer with the BUZ STOP key and acknowledge
the alarm with ACK key. NO ALARM appears in the information area on the
Bridge Panel.
Note: Make sure to operate the ACK key. The audible and visual alarms are sent
to the quarters of all navigation officers and all public areas if only the BUZ STOP
key is operated.
7. If the operations at step 6 are not done within the selected time interval, the audi-
ble and visual alarms are then sent to the Cabin Panel in the quarters of all navi-
gation officers. This interval is set on the Administrator Menu. See Chapter 4.
8. Stop the buzzer and acknowledge the alarm with the BUZ STOP and ACK keys
on the Bridge Panel.
2.6 Help Area
The help area displays system failures, operational events, operation help, etc. If mul-
tiple system failures or operational events occur together, they appear in order of pri-
ority. The order from high to low is 1: System failure, 2: Operational events, 3:
Operation help, 4: Pending matters. “Pending” appears for system failure and opera-
tional events, and it means that the reason for an alarm has not been removed.
2.6.1 System failure indications
This section describes how system failures are given and the accompanying operation
flow.
1) The help area shows system failure messages in red:
[FAIL] YYY: xxxxx (YYY is failure ID, and xxxxx is the description of the system
failure). If multiple system failures are found, they are displayed alternately.
WATCH
ALARM
MODE
ONEMAN
BACK-UP
C-OFFICER
BRIDGE
ALARM
BRIDGE ALARM SYSTEM BR-1000
WARNING!
WATCH ALARM
TIME INT
3 MIN
WATCH
ALARM
MODE
ONEMAN
BACK-UP
C/OFFICER
BRIDGE
ALARM
BRIDGE ALARM SYSTEM BR-1000
WARNING!
WATCH ALARM
TIME INTERVAL
3 MIN