Invacare Power Tiger Mobility Aid User Manual


 
SECTION 7—FRONT RIGGINGS
Part No 1134839 57 Power Tiger™
Adjusting Footrest Height
NOTE: Release the footrest locking mechanism and lift the mounting pin out of the mounting tube.
Lay the assembly on a flat surface to simplify this procedure.
Pivot Slide Tube
NOTE: For this procedure, refer to FIGURE 7.6
1. Remove any accessories that are attached to the footrests.
2. Remove the hex screw and coved washer.
3. Position the lower footrest assembly to the desired height.
4. Align the mounting hole in the footrest support, reinsert the hex screw and coved
washer and securely tighten.
5. Repeat STEPS 1-4 for the other footrest.
6. Reinstall any accessories that are attached to the footrest.
FIGURE 7.6 Pivot Slide Tube
70° MFX and 90° Footrests Only
NOTE: For this procedure, refer to FIGURE 7.7 on page 58.
1. Remove any accessories that are attached to the footrests.
2. Remove the socket screw, coved washer and locknut that secure the footplate to the
footrest support.
3. Reposition the footplate to the desire height.
ƽ WARNING
DO NOT overtighten. Footrest must be able to rotate upward from the horizontal
to vertical position.
4. Reinstall the socket screw through the mounting holes of the footplate and footrest
support.
5. Secure the footplate to the footrest support with the coved washer and locknut.
Securely tighten.
Hex Screw
Coved Washer
Lower Footrest Assembly
Footrest Support