Invacare Power Tiger Mobility Aid User Manual


 
SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING
Power Tiger™ 26 Part No 1134839
Troubleshooting - Mechanical
Troubleshooting - Electrical
NOTE: For additional troubleshooting information and explanation of error codes, refer to the
individual Electronics Manual supplied with each wheelchair
SPJ+, SPJ+ w/PSS or SPJ+ w/ACC Joysticks
The joystick information gauge and the service indicator give indications of the type of
fault or error detected by the control module. When a fault is detected, the wheelchair
may stop and not drive. The LEDs on the information gauge may flash in a particular
pattern or the service indicator light will flash. The number or type of flashes indicates the
nature of the error. If multiple errors are found, only the first error encountered by the
control module will be displayed.
Information Gauge Display Diagnostics
WHEELCHAIR VEERS
LEFT/RIGHT
SLUGGISH
TURN/
PERFORMANCE
CASTERS
FLUTTER
SQUEAKS AND
RATTLES
LOOSENESS
IN WHEELCHAIR
WHEELCHAIR 3
WHEELS
SOLUTIONS
X X X X X Check pneumatic tires for correct and equal pressure.
X X X X Check for loose stem nuts/bolts.
X X Check that casters contact ground at the same time.
DISPLAY DESCRIPTION DEFINITION COMMENTS
All LEDs are off. Power is off.
All LEDs are on. Power is on. Fewer than three LEDs on
implies reduced battery
charge.
Information
Gauge
Display