Emerson 705 Pacemaker User Manual


 
43
Reference Manual
00809-0200-4705, Rev AA
Appendix A: Specifications and Reference Data
May 2015
Specifications and Reference Data
Mounting
Transmitters may be attached directly to switch, brackets also permit remote mounting. See
“Dimensional drawings” on page 44.
A.1.3 Frequency input specifications
0 to 10 kHz
A.1.4 Performance specifications
Electromagnetic Compatibility (EMC)
All models
Meets all relevant requirements of EN 61326-1:2006
Vibration effect
Wireless output unaffected when tested per the requirements of IEC60770-1 field or pipeline
with high vibration level (10-60 Hz 0.21mm displacement peak amplitude/60-2000 Hz 3g).
Wireless output unaffected when tested per the requirements of IEC60770-1 field with general
application or pipeline with low vibration level (10-60 Hz 0.15mm displacement peak
amplitude/60-500 Hz 2g).
Temperature limits
Description Operating limit Storage limit
Without LCD Display –40 to 185 °F
–40 to 85 °C
–40 to 185 °F
–40 to 85 °C
With LCD Display –4 to 175 °F
–20 to 80 °C
–40 to 185 °F
–40 to 85 °C