Reference Manual
00809-0200-4705, Rev AA
Appendix A: Specifications and Reference Data
May 2015
41Specifications and Reference Data
Appendix A Specifications and Reference
Data
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 41
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 44
Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 46
A.1 Specifications
A.1.1 Functional specifications
Wireless output
IEC 62591 (WirelessHART
®
) 2.4 GHz DSSS
Radio frequency power output from antenna
External (WK option) antenna: Maximum of 10 mW (10 dBm) EIRP
Extended Range, External (WM option) antenna: Maximum of 18 mW (12.5 dBm) EIRP
High Gain, Remote (WN option) antenna: Maximum of 40 mW (16 dBm) EIRP
Local display
The optional integral LCD display can display discrete state and diagnostic information. Display
updates at each wireless update or constantly when the device has the optional LCD always on
option.
Humidity limits
0–99% relative humidity
Wireless update rate
User selectable, 1 sec. to 60 min.