Index ACCU-CHEK Spirit Insulin Pump198
program
profile no. 5
program
profile no. 4
program
profile no. 3
program
profile no.2
Standard
bolus
stop your
Accu-Chek
«Scroll» Stan-
dard bolus
bolus
amount
Extended
bolus
bolus
amount
bolus
duration
temporary
basal rate
percentage
duration
select the
user menu
user menu
BR profile
no.…
information
menu
bolus
history
alarm
history
daily insulin
totals
TBR history
maintenance
set the time
and date
set the
hour
set the
minute
set the
year
set the
month
set the
day
setup menu
standard
display
orientation
KeyLock
beep
volume
alarm
signals
automatic
off
battery
type
program
profile no. 1
daily basal
rate total
1st hour
2nd hour
…
24th hour
KeyLock
quick info
MultiWave
bolus
bolus
amount
immediate
bolus
bolus
duration
change your
BR profile
BR profile
no. …
alarm clock
alarm
occurance
alarm
hour
alarm
minute
setup menu
advanced
time
format
date
format
bolus
increment
prime
quantity
basal
rate lock
language
display
contrast
Standard
bolus
stop your
Accu-Chek
«Scroll» Stan-
dard bolus
b
olus
a
mount
temporary
basal rate
p
ercentage
d
uration
select the
user menu
user menu
B
R profile
n
o.…
information
menu
b
olus
h
istory
a
larm
h
istory
daily insulin
totals
T
BR history
maintenance
set the time
and date
set the
hour
s
et the
m
inute
set the
year
s
et the
m
onth
set the
day
setup menu
standard
display
orientation
KeyLock
b
eep
v
olume
alarm
signals
a
utomatic
o
ff
battery
type
program
profile no.1
d
aily basal
r
ate total
1
st hour
2nd hour
…
24th hour
KeyLock
q
uick info
Your Insulin pump ADVANCED MENU
Your Insulin pump STANDARD MENU
Standard
bolus
KeyLock
quick info
stop
priming
p
rime the
i
nfusion set
start
priming
c
ommuni-
c
ation
data transfer
to PC
returning the
piston rod
c
hange the
c
artridge
remove the
cartridge
fill volume
3
15 units
start-up
p
rocedure
start your
Accu-Chek
KeyLock
quick info
start your
Accu-Chek
stop
priming
prime the
infusion set
start
priming
communi-
cation
data transfer
to PC
returning the
piston rod
change the
cartridge
remove the
cartridge
fill volume
315 units
start-up
procedure
(A) «Quick» with direct access from the RUN screen
Standard bolus usingthe a and s keysof your
insulin pump.
(B) «Scroll» menu-guided usingthe STANDARDBOLUS
Standard bolus menuand the scroll function of the a and s
keys for programmingthe bolus amount.
For acomplete review of your insulin pump features aswell as
the warnings and precautions associated with its use,please
refer to your ACCU-CHEK Spirit Insulin PumpUser Guide.
Diagram of User Menus
199
Quick Reference Table for Alerts
In all cases, turn off and confirm the alert prior to addressing the issue.
No. Alert What You Need to Do
A1 CARTRIDGE LOW Change cartridge before it is completely
empty.
A2 BATTERY LOW Replace the battery as soon as possible.
A3 REVIEW TIME AND DATE Set the time and date.
A4 ALARM CLOCK Put your ACCU-CHEK Spirit in RUN mode,
if necessary.
A5 PUMP TIMER Your pump’s operating time will expire
soon. Go to the INFORMATION screen on
your pump, then move to the PUMP TIMER
screen. The days until the pump timer
expires is shown. Make arrangements for
replacement of the pump before the timer
reaches zero days.
A6 TBR CANCELLED Put your ACCU-CHEK Spirit insulin pump in
RUN mode, if necessary. Ensure the can-
cellation was intended and program a new
Temporary Basal Rate, if necessary.
A7 TBR OVER Decide whether a further Temporary Basal
Rate change is appropriate and program
one, if necessary.
A8 BOLUS CANCELLED Put your ACCU-CHEK Spirit insulin pump in
RUN mode, if necessary. Ensure that the
cancellation was intended and program a
new bolus, if necessary.
Quick Reference Table for Alerts ACCU-CHEK Spirit Insulin Pump