3) Install the sealing o-ring and regulator mount nut.
Do not tighten the nut at this time.
4) Tighten the screws that connect the exhaust main
body to the quad exhaust cover.
5) Install the oral nasal mask per this chapter.
6) Install the nose block device per chapter 8.
7) Install the bent tube assembly, per this chapter.
8) Tighten the regulator mount nut to 75 inch
pounds.
9) Install the screws, kidney plates and whisker spac-
ers from the whiskers. Tighten the screws to 12 inch
pounds.
Tighten the screws that connect the quad exhaust
cover to the exhaust body.
Connect the bent tube assembly and tighten at both
ends.
Tighten the screws that fasten the whiskers to the
helmet.