Kirby 37 Oxygen Equipment User Manual


 
111
Kirby Morgan 37 & 57
© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001
Main tube
Lever
o-ring
o-ring
o-ring
Balance
spacer
Spring
Seat
Inlet valve
Adjustment nipple
Bearing
clip
8) Remove the adjustment shaft from the flex knob.
With the shaft out, grab the packing nut with one
hand and the flex knob with the other and bend.
There is a boss on the knob that will pop loose from
the packing nut.
9) Remove the o-rings from the adjustment shaft and
packing nut.
10) Remove the lever by gently pulling one leg out
from the slot on the main tube, followed by the sec-
ond leg.
9) Remove the bearing clip from the main tube.
10) Slide the balance spacer, spring, inlet valve as-
sembly out from the main tube.
11) Unscrew the adjustment nipple from the main
tube.
12) Remove the o-ring from the balance spacer.
13) Remove the o-ring from the main tube.
14) Unscrew the adjustment nipple from inside the
main tube and remove the o-ring from the nipple.
15) Remove the retainer ring from the regulator
body.
16) Remove the exhaust valve insert from the regu-
lator body and separate the exhaust valve from the
insert.
17) Inspect all parts for signs of wear or damage and
replace if necessary.
18) Clean all parts per chapter 6. Lubricate o-rings
and moving parts with a light coating of Christo-
Lube®.
Details of the SuperFlow 450 main tube and
associated parts.