Kirby 37 Oxygen Equipment User Manual


 
108
© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001
Kirby Morgan 37 & 57
26) Inert the adjustment nipple into the main tube
on the end opposite end from the adjustment knob.
Using a flat blade screwdriver, thread the nipple into
the tube slowly.
As soon as you see any movement of the lever stop
screwing the nipple in. Turn in on the flex knob until
an audible click is heard.
27) It is recommended that the regulator sit for 24
hours before any further assembly is completed. This
will allow the seat to conform itself correctly to the
inlet nipple.
28) Bend the lever down and carefully install this
assembly of the main tube and adjustment knob into
the regulator until the threaded end of this assembly
comes completely through the opposite side of the
regulator body.
29) Install the o-ring and the bent tube adapter and
tighten to 30 inch pounds.
30) Tighten the packing nut at the flex knob with a
one inch wrench to 30 inch pounds.
31) Install the lock clip on the main tube.
32) Adjust the regulator per this chapter.
33) Reinstall the diaphragm, cover and cover retain-
ing ring.
34) Reinstall the bent tube assembly as per this
chapter.
35) Once the regulator is properly adjusted, reinstall
the washers and screws that secure the regulator cover
and ring. Tighten the screws to 12 inch pounds.
Install the o-ring in the bent tube adapter.