7.7.9 Reassembly of the SuperFlow 350
Demand Regulator
NOTE: Use the blow-apart in the back of the
manual to help ensure correct assembly.
1) Install the exhaust flange, gasket, and screws onto
the regulator body. Use Loctite 222 to secure the
screws. Tighten the screws to 6 inch pounds.
2) Trim off any excess material from the gasket that
might interfere with the operation of the exhaust
valve.
3) Install the new exhaust valve into the regulator and
trim off any excess stem that may interfere with the
movement of the lever or inlet valve.
The gasket must be installed between the flange
and regulator body.
Be sure to use Loctite to install the screws in the
regulator body.
The screws that hold the flange on the regulator
body should be tightened to six inch pounds.
If the flange is tightened too much, the gasket
will protrude into the exhaust valve opening and
interfere with proper regulator performance.
The exhaust valve is installed on the outside of the
flange.