Kirby 37 Oxygen Equipment User Manual


 
109
Kirby Morgan 37 & 57
© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001
7.12.4 SuperFlow 450 Regulator Removal
Required Tools:
11/16 inch Open-end Attachment on Torque
Wrench
7/8 inch Open-end Wrench, Torque Wrench and 1
3/8 inch Socket
1 /4 inch Flat Blade Attachment on Torque Screw-
driver
1) Remove the bent tube assembly, per this chapter.
2) Remove the screws, kidney plates and whisker
spacers from the whiskers.
Be sure to remove and set aside the whisker
spacers.
3) Remove the nose block device per chapter 8.
4) Remove the oral nasal mask per this chapter.
5) The regulator mount nut is removed along with the
sealing O-ring.
6) Cut the tie wrap that connects the regulator body
to the Quad Valve cover.
7) Now the regulator assembly can be pulled out of
the helmet.
8) The center section of the exhaust whisker, named
the exhaust main body has a tie wrap holding it in
place. Remove the tie wrap then stretch the body off
the regulator exhaust flange.
Remove the regulator from the helmet.
Separate the regulator from the Quad valve
exhaust whiskers.