Kirby 37 Oxygen Equipment User Manual


 
103
Kirby Morgan 37 & 57
© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001
Turn the adjustment nipple 1/16 of a turn at a time
to adjust the performance of the regulator.
7.12.2 Adjusting the SuperFlow 450
Tools required:
Flat blade screwdriver
11/16 inch Open-end Attachment on Torque
Wrench
7/8 inch Open-end Attachment on Torque Wrench
7/8 inch Open-end Wrench
1 inch Open End Wrench
1/4” to 5/16” Dowel Rod sharpened by pencil sharp-
ener
1) Remove the bent tube assembly from the helmet,
per this chapter.
2) Remove the bent tube adapter.
3) Insert a flat head screwdriver into slot in the end
of the adjustment nipple.
Remove the bent tube and the bent tube adapter.
Before you reinstall the bent tube, connect the
low pressure hose to the regulator and pressurize
it again. Push in on the regulator cover 1/4 inch.
The regulator should just begin to free flow if it is
properly adjusted.
5) If the regulator began to free flow too easily,
turn the adjustment nipple IN 1/16 of a turn. Only
small adjustments are needed to tune the regulator.
Reconnect the low pressure hose, pressurize it and
test again.
6) If you are unable to obtain a proper adjustment
with the regulator following this procedure, you will
need to disassemble the regulator to check the condi-
tion of the lever.
7) Once the regulator is properly adjusted, reinstall
the bent tube adapter and o-ring. Tighten the adapter
to 30 inch pounds.
8) Reinstall the bent tube assembly as per Section
this chapter.
4) If the regulator did not free flow when the regulator
cover was pushed in, turn the adjustment nipple OUT
1/16 of a turn. Only small adjustments are needed to
tune the regulator. Reconnect the low pressure hose,
pressurize it and test again.