7.12.5 SuperFlow 450 Disassembly
Required Tools:
1” Open end attachment on torque wrench
1/4 inch Flat Blade Attachment on Torque Screw-
driver
3/8” Dowel Rod
1) Remove the screws and washers on either side of
the regulator cover.
2) Unscrew the cover retaining ring.
3) Remove the cover and diaphragm. Inspect the
diaphragm for holes or tears. If it torn or punctured it
must be replaced. Inspect the interior of the regulator
for foreign matter and remove if necessary.
4) Carefully insert the tip of a flat blade screwdriver
in the slot at the top of the lock clip and slide the clip
away from the regulator main tube.
5) Using the 1” open end wrench, loosen the pack-
ing nut about 1 turn. While depressing the lever arm,
grasp the flex knob and pull it straight away from
the regulator body. This will remove all of the main
components of the regulator valve mechanism as a
single, easy to handle unit.
6) Unscrew the flex knob assembly from the main
tube.
7) Loosen the packing nut on the flex knob and un-
screw the packing nut. Hold the packing nut while
turning the flex knob clockwise. You will notice the
internal adjustment shaft will travel outward AWAY
from the packing nut.
This shaft may not fall out so after about 10 revo-
lutions of the knob. It will be possible to grab the
chamfered tip of the shaft and pull it straight out
from the assembly.
Remove the cover retaining ring and regulator
cover.
Remove the lock clip from the interior of the
regulator.
Unscrew the packing nut from the regulator body.
SuperFlow 450 flex knob assembly.