Hardware Installation
2−19CM 4000 Installation and Operating Manual
Software Configuration
The CM 4000 connected to the Encore must be configured using the Network Description table (page 5−27) and Serial Proto-
col table (page 5−30).
When Jupiter is controlling Encore, the Serial protocol setting is: GNP (Grass Valley Native Protocol), 9600 baud.
The router must be defined on the Switcher Description table (page 5−35). From that point, switcher inputs, outputs, a CP
Level Set, and CP input/Output Sets must be defined.
Note: If Encore is controlling Jupiter, different software settings are required. See page 2−91.
Redundant Installation
Some Encore systems may be equipped with redundant System Controller Boards (SCBs). In this case, the recommended
arrangement is to install a redundant CM 4000 and connect the CMs to the SCBs with a BOP 4000 Break Out Panel. See Figure
2−22.
Figure 2−22. Connection to redundant
Encore Control System. See following
figures for cable variations.
to routing switcher
Encore Redundant SCBs
Redundant CM 4000 System Controllers
RS−422
ports
Serial Port
Serial Port
BOP 4000 Break Out Panel
LAN LAN
Details of the Encore connection are presented below.