A&D AD-4405 Scale User Manual


 
Page 62 AD-4405 Weighing Indicator
16.3.3. Commands to Set Parameters
Set
Set Set
Set the
the the
the Limit/Setpoint Value
Limit/Setpoint ValueLimit/Setpoint Value
Limit/Setpoint Value
Sets the limit or setpoint value of the comparison. The decimal point is not necessary.
Template Sm,n, [ value ]
m: code memory number, 0 - 4
n : setpoint order number, refer to "Setting the setpoint"
Command
Reply
Set
Set Set
Set the
the the
the Zero Band
Zero BandZero Band
Zero Band
Sets the F26 value (zero band) of the comparison. The decimal point is not
necessary.
Template SZ, [ value ]
Command
Reply
Set
Set Set
Set the
the the
the Pres
PresPres
Preset Tare
et Tareet Tare
et Tare
Sets the preset tare value. The decimal point is not necessary.
Template PT,m, [ value ]
m: code memory number, 0 - 4
Command
Reply
Set
Set Set
Set the
the the
the Unit Weight for Counting Mode
Unit Weight for Counting ModeUnit Weight for Counting Mode
Unit Weight for Counting Mode
Sets the unit weight value with decimal point.
Template UW,m, [ value ]
m: code memory number, 0 - 4
Command
Reply