A&D AD-4405 Scale User Manual


 
Page 58 AD-4405 Weighing Indicator
16.3.
16.3.16.3.
16.3.
Command Format
Command FormatCommand Format
Command Format
Explanation of Command
Explanation of CommandExplanation of Command
Explanation of Commands
ss
s
When performing a command, the received command or replay data is sent
back.
When the received command can not be performed such as the "busy" state, the
code " I " is sent back. In this case, insert a delay time. Electrical noise may be
the cause of this error.
When receiving an undefined command (unknown command), a "?" is sent back.
When there is insufficient memory to store the data of the UFC commands, an
M is sent back.
Optional addresses can be appended to a command. The address form is
"@address" and the address is specified at F-Function F06. The reply (data or
error code) is also sent with the address.
Example: The command is "Display net data". The address is 23.
Sending a command Sending a command with address
Unperformed command reply Unknown command reply
Memory overflow (for UFC commands)
16.3. Command Format
M
Terminators
Memory overflow error
Carriage return(0Dh)
Line feed(0Ah)
I
Unperformed command
Terminators
N M
Terminators
Command
Terminators
Command
NM@ 2 3
Address number
Unknown command
Terminators
?
@ 2 3
Address number