A&D AD-4405 Scale User Manual


 
Page 40 AD-4405 Weighing Indicator
10.1.2. Setting the Upper/Lower Limit Values
Step 1 By pressing the SETPOINT key, the selected code memory number is displayed
and the first comparison class term (ex. Hi, TG etc.) is blinking.
Step 2 Select the comparison class using the following keys:
SETPOINT key ........The key to select a comparison class.
ESC key ..................The key to return to the previous stage (weight display or
code memory number select).
ENTER key..............The key to proceed to step 3.
Step 3 Set the setpoint values using the following keys:
0 - 9 key..................The key to enter a value.
ESC key ..................The key to proceed to the next comparison class (step 2)
without changing the set value.
ENTER key..............The key to store the value and proceed to the next
comparison class (step 2).
Set
SetSet
Setting Order and Display for Weight Check Mode
ting Order and Display for Weight Check Modeting Order and Display for Weight Check Mode
ting Order and Display for Weight Check Mode
f22
MODE Display 1 2 3 4 5
1 Upper Setpoint Upper Lower
Lower 1 Class Hi Lo
Comparator HI LO
2 Upper Setpoint Target Upper Lower
Lower 2 Class TG Hi Lo
Comparator OK HI LO
3 Upper Setpoint Target Upper Lower
Lower 3 Class TG Hi Lo
Comparator OK HI LO
Unit % %
4 5-stage Setpoint HiHi Hi Lo LoLo
1 Class HH Hi Lo LL
Comparator HI HI LO LO
Triangle 2 3
5 5-stage Setpoint Target HiHi Hi Lo LoLo
2 Class TG HH Hi Lo LL
Comparator OK HI HI LO LO
Triangle 2 3
6 5-stage Setpoint Target HiHi Hi Lo LoLo
3 Class TG HH Hi Lo LL
Comparator OK HI HI LO LO
Unit % % % %
Triangle 2 3
10.1. Weight Check Mode