A&D AD-4405 Scale User Manual


 
AD-4405 Weighing Indicator Page 23
6.2.
6.2.6.2.
6.2.
F
FF
F-
--
-Functions
FunctionsFunctions
Functions
Weighing Conditions (Digital Filter, Zero trucking and Stability)
Item
Parameter
Description
0
2 d/ 1.6s
1
4 d/ 1.6s
2
8 d/ 1.6s
3
16 d/ 1.6s
4
32 d/ 1.6s
5
64 d/ 1.6s
6
128 d/ 1.6s
7
2 d/ 3.2s
**8 4 d/ 3.2s
9
8 d/ 3.2s
10
16 d/ 3.2s
11
32 d/ 3.2s
12
64 d/ 3.2s
f00
Filter
Motion / Averaging
time
13
128 d/ 3.2s
If weak filter is set, the response
will be fast, but will be more
sensitive to external influences
such as vibration.
0
OFF
1
0.5 d/ 1s
2
1.0 d/ 1s
3
1.5 d/ 1s
4
2.0 d/ 1s
5
2.5 d/ 1s
6
0.5 d/ 2s
7
1.0 d/ 2s
**8 1.5 d/ 2s
9
2.0 d/ 2s
f01
Zero tracking
10
2.5 d/ 2s
This function traces the weight
value drifting around the zero
point slowly, displayed as zero. If
a strong parameter is set, a very
small zero drift may be not
detected.
If Cf00 1 is, the f01 0, 1, 6 or 7
can be selected only.
If Cf00 1 is, the initial setting is
f01 7.
0
No motion detection
1
0.5 d/ 0.5s
2
1.0 d/ 0.5s
3
2.0 d/ 0.5s
4
3.0 d/ 0.5s
5
4.0 d/ 0.5s
6
0.5 d/ 1s
7
1.0 d/ 1s
**8 2.0 d/ 1s
9
3.0 d/ 1s
f02
STABLE mark
Motion detection
condition
10
4.0 d/ 1s
The function to set the condition
of judgment whether a weight
value is unstable or stable. The
ZERO key and TARE key are
active in the stable state. If these
keys need to be active in the
unstable state, set to f02 0 or
select Cf04 1 or Cf04 3. In case
of Cf00 1 is, f02 6 or f02 7 can
be selected only. (Initial setting is
f02 6.)
0
Once after the mark
1
Twice in succession
*2 Three times
f03
Auto Printing/
Auto accumulation
3
Four times
Set the number of times when
the STABLE mark turned on in
succession, until output/print out.
If Cf00 1 is set, f03 2 or f03 3
can be selected.
d: division (weighing interval) of first range. s: second. *: Initial settings.