Fluke 1529 Thermometer User Manual


 
Command Description Refer To
ROUTe:SCAN:MODE? [MIN|MAX|DEF] Returns the current scan mode Section 8.4.3
ROUTe:SCAN:MODE <num>|MIN|MAX|DEF Sets the scan mode Section 8.4.3
SENSe:AVERage:COUNt? [MIN|MAX|DEF] Returns the moving average filter setting Section 8.4.2
SENSe:AVERage:COUNt <num> |MIN|MAX|DEF Sets the moving average filter setting Section 8.4.1
SENSe<chn>:DATA? Returns the input value for the specified channel Section 8.4.1
SENSe<chn>:RESistance:RANGe? [MIN|MAX|DEF] Returns the resistance range setting for the specified
channel
Section 8.4.2
SENSe,<chn>:RESistance:RANGe <num> |MIN|MAX|DEF Sets the resistance range setting for the specified channel Section 8.4.2
SENSe<chn>:RESistance:WIRE? [MIN|MAX|DEF] Returns the probe wire setting for the specified channel Section 8.4.2
SENSe<chn>:RESistance:WIRE <num> |MIN|MAX|DEF Sets the probe wire setting for the specified channel Section 8.4.2
STATus:MEASure? Reads and clears the Measurement Status Register Section 8.4.12
STATus:MEASure:CONDition? Returns the Measurement Status Condition Register Section 8.4.12
STATus:MEASure:ENABle? Returns the Measurement Status Enable Register Section 8.4.12
STATus:MEASure:ENABle <num> Sets the Measurement Status Enable Register Section 8.4.12
STATus:OPERation? Reads and clears the Operation Status Register Section 8.4.12
STATus:OPERation:CONDition? Returns the Operation Status Condition Register Section 8.4.12
STATus:OPERation:ENABle? [MIN|MAX|DEF] Returns the Operation Status Enable Register Section 8.4.12
STATus:OPERation:ENABle <num> |MIN|MAX|DEF Sets the Operation Status Enable Register Section 8.4.12
STATus:QUEStionable? Reads and clears the Questionable Status Register Section 8.4.12
STATus:QUEStionable:CONDition? Returns the Questionable Status Condition Register Section 8.4.12
STATus:QUEStionable:ENABle? [MIN|MAX|DEF] Returns the Questionable Status Enable Register Section 8.4.12
STATus:QUEStionable:ENABle <num> |MIN|MAX|DEF Sets the Questionable Status Enable Register Section 8.4.12
SYSTem:BOOT:VERSion? Returns the boot ROM version Section 8.4.8
SYSTem:CODE:VERSion? Returns the firmware code version Section 8.4.8
SYSTem:COMMunicate:SERial:BAUD? [MIN|MAX|DEF] Returns the serial port baud rate setting Section 8.4.9
SYSTem:COMMunicate:SERial:BAUD
<baud>|MIN|MAX|DEF
Sets the serial port baud rate setting Section 8.4.9
SYSTem:COMMunicate:SERial:FDUPlex? [MIN|MAX|DEF] Returns the serial port echo (duplex) setting Section 8.4.9
SYSTem:COMMunicate:SERial:FDUPlex
<bool>|MIN|MAX|DEF
Sets the serial port echo (duplex) setting Section 8.4.9
SYSTem:COMMunicate:SERial:FEED? [MIN|MAX|DEF] Returns the state of the serial port printing setting Section 8.4.9
SYSTem:COMMunicate:SERial:FEED
<bool>|MIN|MAX|DEF
Sets the state of the serial port printing setting Section 8.4.9
SYSTem:COMMunicate:SERial:LINefeed?
[MIN|MAX|DEF]
Returns the state of the serial port linefeed setting Section 8.4.9
SYSTem:COMMunicate:SERial:LINefeed
<bool>|MIN|MAX|DEF
Sets the state of the serial port linefeed setting Section 8.4.9
SYSTem:COMMunicate:SERial:TIMe? [MIN|MAX|DEF] Returns the serial port sample period setting Section 8.4.9
SYSTem:COMMunicate:SERial:TIMe <num>
|MIN|MAX|DEF
Sets the serial port sample period setting Section 8.4.9
1529 Chub-E4 Thermometer Readout
User’s Guide
82