Instruction Manual
IM-106-910Xi, Original Issue
November 2010
Xi Advanced Electronics
http://www.raihome.com
Section 4 Startup and Operation
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-1
Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-1
Operation via Xi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-2
Startup Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-2
Error Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-2
Xi Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-2
Password Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-3
Xi Menu (Sheet 1 of 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-4
System Parameter Descriptions . . . . . . . . . . . . . . . . . . . . page 4-7
Probe Parameter Descriptions . . . . . . . . . . . . . . . . . . . . . page 4-8
Operation Via HART/AMS . . . . . . . . . . . . . . . . . . . . . . . . . page 4-10
Field Communicator Signal Line Connections . . . . . . . . page 4-10
Field Communicator Menu Trees . . . . . . . . . . . . . . . . . . . page 4-11
Off-line and On-line Operations . . . . . . . . . . . . . . . . . . . . page 4-11
Calibration - General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-14
O
2
Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-14
O
2
Calibration with Xi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-14
O
2
Calibration with Xi and Field Communicator . . . . . . .page 4-15
D/A Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-16
D/A Trim with Xi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-16
OVERVIEW
Interface to the Xi for setup, calibration and diagnostics can be via a 375/475
Field Communicator or Asset Management System.
Setup, calibration and diagnostic operations will differ depending on the
selected interface for communications with the transmitter.
STARTUP
The O
2
Probe will take approximately 45 minutes to warm up to the 736
°
C
heater setpoint. The 4-20 mA signal will remain at a default value of 3.5 mA
through this warm-up period. Once warm, the O
2
probe will be reading
oxygen, and the 4-20 mA signal will be reading based on the default range
of 0-10% O
2
.
NOTE
The Xi offers optional advanced features such as elevated process
temperature capability to 800
°
C, autocalibration via an SPS solenoid box, a
stoichiometer feature for indicating the level of oxygen deficiency in reducing
conditions, and programmable reference to enhance accuracy at near
ambient levels of O
2
.