Emerson 3414 Oxygen Equipment User Manual


 
Daniel 3410 Series Ultrasonic Gas Flow Meter Installation Manual Section 3: Electrical installation
3-9000-759 Rev D June 2014
Frequency/Digital outputs 59
3.6.1 Frequency/Digital outputs
The meter has three user-configurable selections for configuring either a Frequency output or
Digital output (FODO).
FODO1 (four possible parameter configurations)
FODO2 (eight possible parameter configurations)
FODO3 (eight possible parameter configurations)
Frequency or Digital Outputs (FODO 1) source
FO1A, DO1A, FO1B, DO1B
Frequency output 1A is based on frequency content (Actual - Uncorrected Flow Rate)
Frequency output 1B is based on frequency content and Frequency 1 B Phase
Digital output 1A is based on Digital output1A content (Frequency1A Validity or Flow
Direction)
Frequency or Digital Outputs (FODO 2) source
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency output 1A is based on frequency content (Actual - Uncorrected Flow Rate)
Frequency output 1B is based on frequency content and Frequency 1B Phase
Frequency output 2A is based on frequency content (Actual - Uncorrected Flow Rate)
Frequency output 2B is based on frequency content and Frequency 2B Phase
Digital output 1A is based on Digital output1A content (Frequency 1Validity and Flow
Direction)
Digital output 1B is based on Digital output1B content (Frequency 1 Validity and Flow
Direction)
Digital output 2A is based on Digital output 2A content (Frequency 2 Validity and Flow
Direction)
Digital output 2B is based on Digital output 2B content (Frequency 2 Validity and Flow
Direction)