Emerson 3414 Oxygen Equipment User Manual


 
Daniel 3410 Series Ultrasonic Gas Flow Meter Installation Manual Section 2: Mechanical installation
3-9000-759 Rev D June 2014
Meter components 25
2.2 Meter components
Daniel 3410 Series Gas Ultrasonic Flow Meters are assembled, configured and tested at the
factory. The meter components include the transmitter electronics enclosure, the base
electronics enclosure and the meter body with transducer assemblies.
1
1. Refer to the 3-9000-744 Split Clamp Extractor Tool Operation Manual to remove the transducer holders while the
meter is pressurized.
CONTENTS MAY BE UNDER PRESSURE
When the meter is under pressure, DO NOT attempt to remove or adjust the transducer holder.
Attempting to do so may release pressurized gases, resulting in serious injury or equipment damage
CONTENTS MAY BE HAZARDOUS
The meter must be fully depressurized and drained before attempting to remove the transducer holder.
If gas or fluid begins to leak from the transducer holder, stop immediately and reinstall the holder.
Failure to do so may cause serious injury or equipment damage.
A. Transducer holder
A.