Emerson 3414 Oxygen Equipment User Manual


 
34 Use of appropriate safety engineered swivel hoist rings in meter end flanges
Section 2: Mechanical installation Daniel 3410 Series Ultrasonic Gas Flow Meter Installation Manual
June 2014 3-9000-759 Rev D
When lifting a Daniel Ultrasonic Meter by itself, Daniel recommends two methods. These
methods are:
Using appropriately rated Safety Engineered Swivel Hoist Rings installed in the Daniel
Ultrasonic Meter end flanges.
Using appropriately rated lifting slings positioned at designated areas of the Daniel
Ultrasonic Meter.
Both methods must be used in conjunction with all appropriate company hoisting and rigging
standards or the DOE-STD-1090-2004 HOISTING AND RIGGING
standard if such company
standards do not exist. Refer to the following sections for more information on these two
methods.
2.4.1 Use of appropriate safety engineered swivel hoist rings in
meter end flanges
Daniel Ultrasonic meters come equipped with a tapped hole located on the top of each meter
body end flange. A flat machined surface surrounds each tapped hole. This feature provides
complete surface contact ONLY between the meter flange and an OSHA compliant Safety
Engineered Swivel Hoist Ring as shown in Figure 2-9.
Operators SHALL NOT use Eye Bolts (see Figure 2-9) in the Daniel Ultrasonic Meter flange tapped
holes to aid in lifting or maneuvering the unit.
Operators SHALL NOT use other Hoist Rings that do not fully seat flush with the counter bore on
the top of the meter flanges.
Figure 2-8 Meter end flange with tapped flat-counterbore hole for hoist ring
A. Plug Bolt
B. Flat Counterbore Surface
A.
B.