Emerson 3414 Oxygen Equipment User Manual


 
Daniel 3410 Series Ultrasonic Gas Flow Meter Installation Manual Section 1: Introduction
3-9000-759 Rev D June 2014
Meter specifications 13
Specifications for Daniel 3410 Series Gas Ultrasonic Flow Meters are below:
Table 1-2 Meter specifications
Daniel 3411, 3412 and 3414 meter specifications
Meter type Number of paths
3411 Daniel single path (two transducer) or center-line (bounce) design
3412 Daniel two path (four transducer) center-line (bounce) design
3414 Daniel four path (eight transducer) chordal design
Ultrasonic type
Transit-time based measurement
Spool piece with integral mount transducers
Enclosure materials ASTM B26 Gr A356.0 T6 Aluminum
100% conversion coated and exterior coated with a polyurethane enamel
ASTM A351 Gr CF8M Stainless Steel
—Passivated
Optional Local Display with a glass endcap on transmitter enclosure
Meter Performance
Linearity
Model 3414 Four-path meter chordal design
± 0.3% of measured value over a 100:1 turndown 3-100 ft/s; 0.3 to 30 m/s) including lab
uncertainty
Flow calibrated accuracy is ± 0.1% of reading relative to lab over entire flow calibration
range (Q
min
- Q
max
)
Model(s) 3411 single-path or 3412 two-path
Flow calibrated accuracy is ± 0.5% of reading relative to lab
1
Accuracy is typically ±1.5% of actual volume flow
1
(without flow calibration)
1. Does not take into consideration changes in wall roughness and installation effects.
Repeatability
±0.05% of reading in the specified velocity range from 5% to 100% (Q
max
)
Velocity range
100 ft/s (30 m/s) with over-range)
125 fps (38 m/s) on some line sizes
Meter meets or exceeds AGA9 (2007) performance specifications
Body and Flange Sizes and
Pressure rating range
U.S. Customary Units - Meter sizes 4, 6, 8, 10, 12, 16, 18, 20, 24, 30, and 36 (inches)
ANSI pressure classes 300, 600, 900 and 1500 (per ANSI B16.5)
Carbon Steel
316 Stainless Steel
Metric Units - Meter sizes DN - 100, 150, 200, 250, 300, 400, 450, 500, 600, 700, 750, 900
PN 50, 100, 150, 200
Carbon Steel
316 Stainless Steel
Maximum Pressures
Dependent on operating temperature
Meter bore
Schedule 20, 30, 40, 60, 80, 100, 120, 140, 160, STD, XS, LW
Table 1-3 Performance specifications
Meter size 4” to 24” 30” 36”
Qmin(ft/s) 222
Qt (ft/s) 10 8.5 7.5
Qmax (ft/s) 100 85 75