Invacare Ranger II250 SERIES Wheelchair User Manual


 
28
FIGURE 2 - ADJUSTING LIMIT SWITCH
5
o
Seat Angle
24
o
Back
Recline Angle
61
o
Magnetic Protractor - (Will
read 61
o
when back recline
angle is at 114
o
relative to the
seat frame)
Upper Limit
Switch
Bracket
Phillips
Screws,
Washers
and Lock-
nuts
Actuator
114
o
5-3/4 inches
PROCEDURE 8 LIMIT SWITCH
L
I
M
I
T
S
W
I
T
C
H
D. Only tighten the two (2) phillips screws, washers
and locknuts that secure the actuator to the up-
per limit switch bracket until the actuator does not
move.
E. Repeat STEPS 1-3 until the wheelchair does not
operate when the captain's seat back is at a 24
o
angle.