3.8 Entering Analog Inputs
The Analog Input option enables you to specify parameters for general
purpose or energy inputs. To enter the Inputs option, scroll to the Analog
Input entry on the Program Menu and press
[ENTER]. If you have not
enabled the Energy Option (see page 42), the screen appears similar to
Figure 26 below. To step through each parameter, press the [T] key. Refer
to Figure 148 on page 232 of Appendix A, Menu Maps.
3.8.1 Entering General-Purpose Analog Inputs
Figure 26: Analog Inputs Option Window
1. The first prompt asks you to select whether the desired function is off or
general purpose.
a. Press [ENTER] to open the drop-down menu.
b. Scroll to the desired response.
c. Press [ENTER] to confirm your selection.
Analog Input
Cancel OK
Function
Units
Span
Label
Zero
100
Inlet Temp
°C
General Purpose
*C
0
°C
Input A Input B