AMX RE-DM4 Light Therapy Device User Manual


 
AMX RADIA Lighting Programming
39
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
Stop Ramping Preset
This function stops the ramping of the most recently ramped preset.
Recall Preset
This function recalls the specified preset over an optionally specified time.
If time is not specified, then the rate used when saving the preset used.
Record Preset
This function records the current level of all "defined" dimmers and associates them with the specified preset.
An optional time parameter may be specified to record the specified rate at which the preset is to be
recalled.
If time is not specified, then the default preset rate value at the time of the preset recording will be
used when recalling the preset as set by the "PT" command.
Level Status
This function returns the current dimmer levels of all dimmers.
All level values are returned as a percentage (0-100).
If <pack> is specified, it must be 1.
Stop Ramping Preset
String: PS
Response: PRESET <preset> RAMP STOP
Example: SEND_STRING Radia,"'PS',13" Stop ramping preset
Response: "12,'PRESET 001 RAMP STOP',13,10,'?'" (if preset 1 was ramping)
Recall Preset
String: <preset>B[<time>]
Response: GOTO <preset> in <time>
Examples:
SEND_STRING Radia,"'2B',13" Recall preset 2 at the saved rate
Response: "12,'GOTO 002 in 5',13,10,'?'"
SEND_STRING Radia,"'56B10',13" Recall preset 56 over 10 seconds
Response: "12,'GOTO 056 in 10',13,10,'?'"
If no time was specified for recording the preset or recalling the preset, the preset will
be recalled using the default time when the preset was saved.
Record Preset
String: <preset>R[<time>]
Response: RECORD <BEL> <preset> IN <time>
Examples:
SEND_STRING Radia,"'3R',13" Record preset 3 at default rate
Response: "12,'RECORD ',7,'003 IN 5',13,10,'?'"
SEND_STRING Radia,"'32R3',13" Record preset 32 with 5 second ramp
Response: "12,'RECORD ',7,'032 IN 3',13,10,'?'"
Level Status
String: [<pack>]Z
Response: P<pack>:<level1>,<level2>,<level3>,<level4>,<level5>,<level6>
Example:
SEND_STRING Radia,"'Z',13" Request level status