AMX RE-DM4 Light Therapy Device User Manual


 
Radia Eclipse Dimmer Modules
2
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
RE-DM4 Specifications
Suggested Loads
RE-DM4 Specifications
Dimensions (HW) 5.75" x 10.0" (146.50 mm x 254.00 mm)
Line Input 120, 240 VAC, single phase, 2W+G, 50/60 Hz, 2400 W, one feed
120, 120/240, 240 VAC, single phase, 3W+G, 50/60 Hz, 4800 W, dual feed
Output 1200 W max. per channel @120, 240 VAC
2400 W max. total, all four channels on with single 2400 W feed
4800 W max. total, all four channels on with dual 2400 W feeds
Line input #1 goes to dimmer 1 and 3; line input #2 goes to dimmer 2 and 4
All electrical ratings are for continuous duty
Wire rating Use only copper wires rated at 75°C (167°F) min.
Torque terminals To 20 in-lbs (2.3 N/M)
Maximum wire size 10 AWG (4 mm²)
Wire stripping length 0.5" (13 mm)
AxLink Port 4-pin 3.5mm black captive wire connector. AxLink communication
signaling with 12VDC power in.
Aux Power 2-pin 3.5mm green captive wire connector. This is a 12VDC power input that supplies
additional power to the Radia PCB and connected Radia modules.
Dry Contacts Emergency fire alarm relay connection - Closed relay activates preset 126.
Other control is locked out until relay opens.
Supports daisy chaining of up to 20 dimmers for this connection, with a maximum
current requirement of 200mA when daisy-chained.
Failsafe connection - Works with a toggle switch - opening the switch triggers preset
128, closing the switch triggers preset 127.
Supports daisy chaining of up to 20 dimmers for this connection with a maximum
current requirement of 200mA when daisy-chained.
BTU/hr 300 single feed (2400 W);
600 dual feed (4800 W)
Idle current draw 75 mA @ 120 VAC,
50 mA @ 240 VAC, 100 mA VDC
RDM control current 2 at 200 mA @ 12 VDC with no additional power supply
Certifications FCC
•CE
IEC-60950 Safety
UL North America
Operating Temp Range 0° to 40°C (32° to 104°F)
Included Accessories 2 4-pin 3.5mm captive wire connector (41-5047)
4 #8-32x1/2” F-point mounting screws
Required Enclosures RDA-ENC2 (FG606-10)
RDA-ENC4 (FG606-11)
RDA-ENC6/6B (FG606-12/13/15)
RDA-ENC12B (FG606-14/16)
Dimmed Switched
Incandescent Motors
Neon, cold-cathode Fans