A SERVICE OF

logo

IN1606 Scaling Presentation Switcher • SIS Communication and Control 43
Command ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Information Request
General Information
I
VidX!
AudX!
TypX#
StdX1)
BlkX2*
...
HrtX1#
VrtX1#]
Query firmware version
Q
x.xx]
View firmware version.
Query full firmware
version
*Q
x.xx.xxxx]
View full firmware version.
Query part number
N
60-1081-01]
View the device part
number.
View internal
temperature
E20STAT} X1!]
View the temperature in
degrees Celsius.
Backup or Restore Configuration
Save box configuration
to file system
E1*{config type}XF} Cfg1*{config type}]
Backup device
configuration.
Restore box
configuration from file
system
E0*{config type}XF} Cfg0*{config type}]
Restore device
configuration.
NOTE: {config type} = 0 = IP config, 2 = box-specific parameters.
Device Naming
Set unit name
24
EX1$CN} Ipn
X1$]
Set the device name to
X1$.
Set unit name to factory
default
24
E
CN} Ipn
X3#]
Reset the device name to
the factory default.
View unit name
ECN} X1$]
View the current device
name.
NOTES:
X! = Input selection 1-6
X# = Input video format 1 = RGB
2 = YUV
3 = RGBcvS
4 = S-video
5 = composite
6 = HDMI
X1) = Input standard 0 = no signal detected on the current input
1 = NTSC 3.85
2 = PAL
3 = NTSC 4.43
4 = SECAM
- = not applicable (occurs when the input is active RGB,
YUV, or HDMI signals)
X1! = Internal temperature In degrees Celsius
X1# = Horizontal and vertical frequencies
X1$ = Text label Up to 63 characters
X2* = Video mute 0 = off or disabled
1 = on or enabled (mute to black)
2 = mute all output sync
X3# = Default name A combination of model name and the last 3 pairs of the
MAC address