![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/7d/17d45f10-afe3-475c-9582-d009edfb8725/17d45f10-afe3-475c-9582-d009edfb8725-bg25.png)
IN1606 Scaling Presentation Switcher • SIS Communication and Control 29
X3)
= HDCP status
0 = no sink or source device detected
1 = sink or source detected with HDCP
2 = sink or source detected but no HDCP is
present
X3!
= Video switching effect
0 = cut
1 = fade through black (default)
X3@
= HDMI output format
0 = auto (based on the display EDID: default)
1 = DVI RGB 444
2 = HDMI RGB “Full”
3 = HDMI RGB “Limited”
4 = HDMI YUV 444 “Full”
5 = HDMI YUV 444 “Limited”
6 = HDMI YUV 422 “Full”
7 = HDMI YUV 422 “Limited”
X3#
= Default name A combination of model name and the last
three pairs of the device MAC address (for
example, IN1606-07-8C-EC)
X3%
= Audio input type
0 = none (input muted)
1 = analog (default for inputs 1 and 2)
2 = LPCM-2Ch digital (default for inputs 3-6)
3 = Multi-Ch digital
4 = LPCM-2Ch digital auto
5 = Multi-Ch digital auto
X3^
= Video signal status
0 = video/HDMI signal not detected
1 = video/HDMI signal detected
X3&
= Power save mode
0 = full power mode (default)
1 = lower power state
X3*
= Screen saver status
0 = active input detected; timer not running
1 = no active input; timer running; output sync
still active
2 = no active input; timer expired; output sync
disabled
X3(
= HDMI input HDCP authorization
status
0 = block HDCP encryption
1 = allow HDCP encryption (default)
X4)
= IP address xxx.xxx.xxx.xxx
(192.168.254.254 = default)
X4!
= Subnet mask xxx.xxx.xxx.xxx (255.255.0.0 = default)
X4@
= Gateway address xxx.xxx.xxx.xxx (0.0.0.0 = default)
X4#
= Volume group number 1 = program volume
3 = mic volume
8 = variable volume
X4$
= Group fader level
-1000-0, where -1000 = -100 dB or 0%
volume and 0 = 0 dB or 100% volume
X4%
= Mute group number 2 = program mute
4 = mic mute
7 = output mute
X4^
= Bass and treble group
number
5 = bass control
6 = treble control
X4&
= Bass and treble level
-240-+120, where -240 = -24 dB and
120 = 12 dB
X4*
= Increment value
dB value multiplied by ten, in 0.1 dB increments,
to raise or lower a group fader (for example, 100
= 10 dB)