![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/7d/17d45f10-afe3-475c-9582-d009edfb8725/17d45f10-afe3-475c-9582-d009edfb8725-bg20.png)
IN1606 Scaling Presentation Switcher • Operation 24
Reset Modes
There are three reset modes (numbered 1, 4, and 5). These are available by pressing the
recessed Reset button on the rear panel (see the following table for a summary of the reset
modes).
ATTENTION: Review the reset modes carefully. Using the wrong reset mode may result
in unintended loss of flash memory programming, port reassignment, or processor
reboot.
NOTE: The reset modes listed close all open IP and Telnet connections and all sockets.
Each mode is a separate function, not a continuation from mode 1 to mode 5.
Reset Mode Summary
Mode Activation Result Purpose/Notes
Use Factory Firmware
1
Hold down the recessed Reset button
for 30 seconds while applying power to
the scaler.
NOTE: After a mode 1 reset,
update the device with the latest
firmware version. DO NOT
operate the firmware version that
results from this mode reset. This
temporarily resets the device
to factory default until power is
recycled. To use factory default
firmware, upload that version
again.
The device reverts to the factory default
firmware:
a. Reverts to the factory default firmware for a
single power cycle.
b. All user files and settings (drivers, audio
and video adjustments, IP settings, etc.)
are maintained.
NOTE: If you do not want to update the
firmware or perform a mode 1 reset by
mistake, cycle power to the device to
return the firmware version running prior
to the reset.
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Reset IP
Settings
4
Hold down the Reset button for about
6 seconds until the Reset LED blinks
twice. Then press Reset momentarily
(<1 second).
IP settings revert to factory defaults.
• Reverts port mapping back to factory
default.
• Turns DHCP off.
• IP address is set to 192.168.254.254.
• Reset LED blinks four times in quick
succession during reset.
Resets all IP settings
back to factory defaults.
Reset to Factory
Default
5
Hold down the Reset button for about
9 seconds until the Power LED blinks
3 times. Then press Reset momentarily
(<1 second).
The device reverts to the factory defaults
except for firmware.
a. Performs everything a mode 4 reset does.
b. Resets all user modifiable configuration
to default values including IP settings and
real-time adjustments.
c. Deletes all user loaded files.
d. The Reset LED blinks 4 times in quick
succession during the reset.
Use mode 5 to
restart with default
configuration. This
is equivalent to SIS
command ZQQQ.