Roland S-1608 Wheelchair User Manual


 
Appendices
68 S-1608/S-0816 Digital Snake Owner’s Manual
S-4000R Unit: System Status Indicators
Indicator
Status Definition Troubleshooting Action
POWER Lit Power is received
None (normal operation)
Dark No power is received
Make sure all REAC devices are turned on
Check the RS-232C cable for damage
Are you using an RS-232C cable with the proper wiring?
(See Appendix B)
REAC Lit Communication is established
None (normal operation)
Flashing System power-up
None (normal operation)
No REAC communication
Make sure all REAC devices are turned on
Check Cat5e cable connections
Check the Cat5e cable(s) for damage
Is the proper cable type being used? (See Page 40)
If a switching hub is used, is it working?
If a switching hub is used, is it properly connected? (See
Page 41, 60)
If a switching hub is used, does it have the proper
specification? (See Appendix C)
CTRL Lit REMOTE communication
established
None (normal operation)
Flashing System power-up
None (normal operation)
No REMOTE
communication
Check the RS-232C cable for damage
Are you using an RS-232C cable with the proper wiring?
(See Appendix B)
S-4000R Unit: Error Indicators
Indicator
Status Definition Troubleshooting Action
CLIP 1/
SIG 1
Lit The REAC connection has failed
Check REAC cabling
Check REAC connections
Check in-line REAC Splitter S-4000-SP or switching hub (if
used) on REAC connection
Flashing Recovery from the above error
None
CLIP 2 Lit An exhaust fan on the Master
REAC unit has stopped working
Check the exhaust fan is working
Turn off the power to prevent overheating and damage
Consult with the nearest Roland Service Center
Flashing Recovery from the above error
None
CLIP 4/
SIG 4
Lit REAC packets error detected on
the unit connected to the
S-4000R
Check REAC cabling
Check REAC connections
Check in-line switching hub (if used) on REAC connections
SIG 2 Lit An exhaust fan on a Slave/ Split
REAC unit has stopped working
Check the exhaust fan is working
Turn off the power to prevent overheating and damage
Consult with the nearest Roland Service Center
Flashing Recovery from the above error
None
CHANNEL
Display
Flashes
“Er”
This happens whenever one of
the previously described
S-4000R error indicators lights
or flashes
Look for the source of the error
Press [CLIP CLEAR / ENTER] to return to normal
S-4000R operation
S-1608_e.book 68 ページ 2007年4月23日 月曜日 午後12時57分