Roland S-1608 Wheelchair User Manual


 
4—Panel Descriptions
S-1608/S-0816 Digital Snake Owner’s Manual 23
4—[CLIP CLEAR / ENTER] Button
The [CLIP CLEAR / ENTER] button is a dual-function button. It’s used to:
clear the clip indicators
—When an input signal connected to one of the system’s audio inputs
exceeds 0 dB (in the digital domain), the corresponding clip indicators on the S-4000R light, and
the [CLIP CLEAR / ENTER] button flashes. To turn off all clip lights, press [CLIP CLEAR / ENTER] so
that it stops flashing.
finalize a selection
—When a selection is made (such as a memory preset), press [CLIP CLEAR /
ENTER] to finalize the selection.
5—[PAD] Button
Press the [PAD] button so its indicator lights to engage a 20 dB pad on the currently selected input
channel.
To disengage the pad, select the desired channel and press the [PAD] button so its indicator goes out.
6—[GAIN] Knob
Use this knob to set the preamp gain for the currently selected S-1608/S-0816 System’s input channel.
Indicator lights surrounding the [GAIN] knob show the current gain setting.
Each S-1608/S-0816 System’s input channel’s gain range is -45 to +10 dBu with the pad on, and -65
to -10 dBu with the pad off.
7—Input Signal Level Meter
This eight-segment LED meter indicates signal level for the currently selected input channel.
8—[LOCK] Button
The [LOCK] button allows you to lock the S-4000R so that input channel settings cannot be altered.
The S-4000R is locked when the [LOCK] button is lit. To unlock the S-4000R, hold the [LOCK] button
until its light goes out.
Although changes may not seem smooth when adjusting preamp gain using an S-4000R or an
S-4000RCS (remote control software) on a computer, this is not a malfunction.
Some noise is also generated when switching between the following gain levels. This is not a
malfunction.
Three locations when Pad=ON: +3
+2, -13
-14, -19
-30 (dBu)
Three locations when Pad=OFF: -17
-18, -33
-34, -49
-50 (dBu)
The S-4000R upgrade allows the gain level to be verified with numerical values.
See the Roland website for the version that supports this feature and how to upgrade.
http://www.rolandsystemsgroup.net
To retain the current S-1608/S-0816 System’s input channel settings, lock the S-4000R before
powering down the S-1608/S-0816 System. When the system is powered up, the settings will return
to the state they were in when the S-4000R was last locked.
S-1608_e.book 23 ページ 2007年4月23日 月曜日 午後12時57分