AGFA HE/001132 Medical Alarms User Manual


 
HE/001132 Page 14 of 92
Document No. 001132, Revision 2.0
Agfa HealthCare NodeID Livelink : 14140190 14 June, 2007
"Workstation" does not foresee additional logic when the system is shut down, regarding storage
commitment time outs. In other words: when a storage commit reply does not reach "Workstation"
successfully, because "Workstation" was/is down at that point in time, the job will time out and go to FAILED.
A Possible sequence of iterations between the DICOM Store AE and an Image Manager is illustrated in
figure 2.2-1
Figure 2.2-1: Example of a Storage AE Sequencing Diagram (with Storage Commit)
The DICOM Store AE may reject the association attempts as shown in the table below:
Store PACS
2. C-STORE (CR Image)
1. Open Associa
tion
3. C-
STORE (GSPS)
5. C-
STORE (GSPS)
4. C-STORE (CR Image)
6. N-
ACTION (Storage Commit Rq)
7. N-EVENT-REPORT (Storage Commit Resp)
8. Close Association
6. Close Association
7. Open Association