48 Control Panel Options
RX2 Reference Guide E-EQ-RX2RG-B
Factory Default Settings
Affects LXE
APIs?
Affects
RFIDApp?
Format
HEX Enabled Yes Yes
EPC Disabled Yes Yes
Field Separator Blank Yes Yes
How to Modify RFID Parameters
Follow this process when modifying the parameters on the RFID Control Panel tabs.
Note: A separate procedure is required when upgrading firmware. This procedure is discussed
later in the “Firmware” tab section.
1. Establish an ActiveSync Remote Display session between the RX2 and a PC.
2. Access the RFID Control Panel (Access: Start | Settings | Control Panel | RFID)
3. If a separate RFID application is running, user may see 0.0 for the Firmware Version
displayed on the Firmware tab. This is normal and does not indicate a problem.
4. Configure RFID settings as desired, press OK to save settings and close the RFID Control
Panels. The RFID tabs are discussed in the following pages.
5. Warmboot the RX2.
Tags
Access: Start | Settings | Control Panel | RFID | Tags tab
Figure 3-12 RFID Properties / Tags Tab
Note: RX2 is restricted to 95% for Modulation. LXE recommends using the default setting of
ID2 for Class 0 Singulation.
A pop up option box is displayed if the user attempts to deselect all tag types. At least one class
must be selected before the user can continue.
Click the Restore Defaults button to set the parameters in the RFID Configuration Utility menu
panels to their factory default settings.