Configuring PAD/ATPAD Ports 5
PAD Port Configuration
Guidelines
When the Port Type is PAD, follow these guidelines for configuring parameter
values of the other port parameters:
Other Tables You
Must Configure
If your port type is PAD Port, you must also configure parameters in the:
PAD Profile Table
PAD Prompt Table
See those sections for information about how to configure those table records.
If You Specify or Set... Then...
Profile Name The entry must exist in the PAD Profile
Table.
Call Control to AUTO or AUTC Autocall Mnemonic must have a value.
Call Control = AUTO and (Port Record)
Connection Type = SIMP,
Maximum Number of Autocall
Attempts must be 0.
Ports as having Call Control = AUTO Configure each port to have different
values for Autocall Timeout.
Terminal Control to PASS An NUI Table entry must exist.
Terminal Control to CUG An entry for CUG Membership must
exist.
PAD Prompt Entry Number The entry must exist in the PAD Prompt
table.
Remote PAD Parameters Number The entry must exist in the Remote PAD
Parameters Table.
Autocall Mnemonic The entry must exist in the Mnemonic
Table.
A Subaddress value It should equal the port number.
Billing Records as On A Billing Printer Mnemonic must be
specified in the Mnemonic Table.