Invacare 9000 SL Mobility Scooter User Manual


 
SECTION 7—RECLINER
Part No. 1076155 65 9000 Series
Replacing Locking Rod
NOTE:Forthisprocedure,refertoFIGURE 7.6.
1. Removethemountingscrewandlocknutthatsecurethelockingrodtothebacktube
mountingbracket.
2. Pulllockingrod/reclinertubeassemblybackward.
3. Removeantirattlefromlockingrod.
4. Whileholdingthelockingrod,squeezereleasehandle.
NOTE:Bysqueezingthereleasehandleandactivatingthereclinemechanism,thelockingrodis
released.
5. Pullexistinglockingrodoutofreclinertubeassembly.
6. Installnewlockingrodintothereclinertube.
7. Slideantirattledownnewlockingrodandpositionontopofthereclinertube
assembly.
8. Pushlockingrod/reclinertubeassemblyforward.
9. Whilesqueezingthereleasehandle,aligntheholesofthelockingrodwiththeholes
inthebacktubemountingbracket.
10. Securethenewlockingrodtothebacktubemountingbracketwithexistingmounting
screwandlocknut.Securelytighten.
FIGURE 7.6 Replacing Locking Rod
Replacing Back Tube
NOTE:Forthisprocedure,refertoFIGURE 7.7.
1. Removethespreaderbar.RefertoStoring/ReplacingtheSpreaderBar
intheownerʹs
manual,partnumber1056953.
Back Tube Mounting
Bracket (STEPS 1,9,10)
Locknut
(STEPS 1,10)
Locking Rod
(STEPS 1,2,4-10)
Anti-Rattle
(STEPS 3,7)
Recliner Tube
(STEPS 2,5,6-8)
Tie-Wraps
(STEPS 4,7)
Mounting Screw
(STEPS 1,10)