Extron electronic DSC 301 HD Scale User Manual


 
Command ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Input presets
Recall preset
2*X2). 2RprX2)]
Recall input preset X2) for selected
input.
Save preset
2*X2), 2SprX2)]
Save input preset X2) for selected
input.
Delete/clear preset
EX2*X2)PRST} PrstX2*X2)]
Clears input preset X2), and sets input
preset X2) name to [unassigned].
Input preset name
Write name
E2*X2),X1#PNAM} Pnam2*X2),X1#]
Set the input preset X2) to X1#.
Read name
E2*X2)PNAM}
X1#]
Read the name for input preset X2).
NOTE: Unassigned presets = “[unassigned]”. To restore a default user preset name, enter a single space character for X1#. Valid only
for previously saved presets.
User Presets Input Presets
Color H/V Image
Position
Color H/V Image
Position
Input Type H Start
Tint H/V Image
Size
Tint H/V Image
Size
Audio Gain/
Attenuation
V Start
Contrast Preset Name Contrast Preset Name Film Mode H Active
Brightness Brightness Total Pixels V Active
Detail Detail Phase
Figure 18. Values Saved in User and Input Presets
Auto memories (per input)
Enable
EX!*1AMEM} AmemX!*1]
Set auto memory on. Previous settings
for incoming signal are auto recalled.
Disable
EX!*0AMEM} AmemX!*0]
Set auto memory off. Manual recall
of input presets needed to configure
input.
View setting
EX!AMEM}
X(]
View current auto memory for input
X!.
NOTE: X! = Input selection: 1 to 3
X( = Enable or disable: 0 = Off or disable, 1 = On or enable
X1# = Text label or preset name, up to 16 characters
X2) = Input presets, 1-128 (global)
DSC 301 HD • SIS Communication and Control 30