3-2 Operation Rosemount Analytical Inc. A Division of Emerson Process Management
Model NGA 2000 TO2
a. Menu Lines & Softkey Functionality
Menu lines can be selected with the key
or the key. The selected line is dis-
played as white lettering on a black back-
ground (reverse text). Menus can contain
four different types of lines:
Menu Line – A line ending with three dots
(…) indicates that it leads to a submenu.
The submenu can be activated by press-
ing the key or the key when the line
is highlighted.
Function Line – A line ending with an
exclamation point (!) indicates that it will
start a function. The function can be acti-
vated by pressing the key or the key
when the line is highlighted.
Variable Line – A line ending with a colon
(:) indicates that it displays a module
variable parameter. Some parameters
can be changed and some parameters
display only a status and cannot be
changed. Paramters that cannot be
changed will be displayed below a line
within the menu.
Text Line – A line without punctuation
marks displays information.
Tag Line – At the top of each menu
screen is the tag line of the current chan-
nel. To the right of the Tag is the value of
the indicated channel.
The Function Keys (Softkeys) can some-
times be assigned as Functions (excla-
mation point) or Submenus (three dots)
as shown in Figure 3-2.
Figure 3-2. The Display Screen
b. Common Function Keys
The function keys are shown in Figure 3-1
And Figure 3-2.
Display – Change from the single com-
ponent display to the multi-component
display. F1 in the single component dis-
play.
Measure – Change from menus and
submenus to the single component dis-
play of the selected channel. F1.
Status – Change to the menu “Current
measurement parameters” which displays
the most important parameters and infor-
mation about the status of the current
channel or module. F2 if available. (See
Section 3-4 )
Main – Change from single component
display to the main menu. F3 in the single
component display. (See Section 3-2e)
HOME – Change for various menus to the
main menu. F1.
Channel – Scrolls through the channels
in the same menu. In the main menu and
the single component display menu it
moves between the channels of the con-
nected Analyzers and Analyzer modules.
In the submenus it moves only between
CLD 7.50 ppm
Measure
Status… Channel Lock… MFG Data
-- Main Menu --
Anal
y
zer basic controls
(
calibration
)
& setu
p
Anal
y
zer and I/O
,
ex
p
ert controls & setu
p
S
y
stem confi
g
uration and dia
g
nostics…
Dis
p
la
y
controls…
Time & Date:
S
y
stem ta
g
:
Menu Line
Function Lines
Variable Lines
Ta
g
Line
Lines below this separator
are information and cannot
be chan
g
ed.
Function Keys F1 – F5 Legend
Selected Line
(Reverse Text)